Skip to content
CISPR 16-1-2

EM5040 Series LISN

Line Impedance Stabilization Networks for EMC Testing

The EM5040 Series is a family of V-type line impedance stabilization networks designed for conducted disturbance voltage measurement in EMC testing. The series supports R&D debugging, compliance validation, and industrial EMC workflows with models optimized for standard CE testing, receiver protection, CM/DM analysis, and high-current single-line applications.

Product FamilyEM5040E / EM5040A / EM5040B / EM5040C
Frequency Range9 kHz to 30 MHz (E/A/B); 100 kHz to 200 MHz (C)
Circuit Type(50uH+5Ω)‖50Ω V-type (E/A/B); (5uH+1Ω)‖50Ω (C)
Get a Quote
EM5040 Series LISN

Stable Impedance for Accurate Conducted Emission Measurement

The EM5040 Series is a family of V-type line impedance stabilization networks designed for conducted emission testing and EMC debugging. These LISNs provide a stable impedance environment for the equipment under test while coupling disturbance signals to external receivers or analyzers for accurate measurement.

The series includes multiple configurations for different workflows. EM5040E provides the standard single-phase LISN function, EM5040A adds a built-in 10 dB limiter and optional 150 kHz high-pass filter, EM5040B adds common-mode and differential-mode separation for advanced debugging, and EM5040C targets high-current, higher-frequency single-line testing for industrial and automotive-related applications.

Model Selection Guide

ModelPositioningKey FunctionBest Fit
EM5040EStandard single-phase LISNBasic V-type LISN for conducted disturbance voltage measurementGeneral CE testing and baseline EMC measurement
EM5040AProtected test setup LISNBuilt-in 10 dB limiter and optional 150 kHz high-pass filterReceiver protection and compliance-oriented workflows
EM5040BAdvanced EMI debugging LISNCM/DM separator for common-mode and differential-mode analysisEMI filter debugging and interference root-cause analysis
EM5040CHigh-current / high-frequency LISN100 kHz to 200 MHz range and 100 A ratingIndustrial, automotive, and high-current EMC test scenarios

EM5040E — Standard LISN

ParameterValue
Frequency Range9 kHz to 30 MHz
Circuit Type(50uH + 5Ω) ‖ 50Ω Type V
Measurement CircuitSingle phase two wire L/N
AC Voltage0 to 264 VAC, 50/60 Hz ±5%
DC Voltage0 to 375 VDC
Current Rating16 A
Output Connector50Ω BNC female
Artificial HandYes
Weight5 kg

EM5040A — Protected LISN

ParameterValue
Frequency Range9 kHz to 30 MHz
Circuit Type(50uH + 5Ω) ‖ 50Ω Type V
Measurement CircuitSingle phase two wire L/N
AC Voltage0 to 264 VAC, 50/60 Hz ±5%
DC Voltage0 to 375 VDC
Current Rating16 A
Output Connector50Ω BNC female
Limiter10 dB, 130 dBuV threshold
High-Pass FilterOptional 9 kHz / 150 kHz
Weight5.25 kg

EM5040B — CM/DM LISN

ParameterValue
Frequency Range9 kHz to 30 MHz
Circuit Type(50uH + 5Ω) ‖ 50Ω Type V
Measurement CircuitSingle phase two wire L/N
AC Voltage0 to 264 VAC, 50/60 Hz ±5%
DC Voltage0 to 375 VDC
Current Rating16 A
Output Connector50Ω BNC female
CM/DM SeparatorYes
Weight5.25 kg

EM5040C — High-Current LISN

ParameterValue
Frequency Range100 kHz to 200 MHz
Circuit Type(5uH + 1Ω) ‖ 50Ω
Measurement CircuitSingle wire
AC Voltage0 to 250 VAC, 0 to 400 Hz
DC Voltage0 to 600 V
Current Rating100 A rated / 500 A short-time
Output Connector50Ω N female
Weight1.8 kg

Typical Applications

  • Conducted disturbance voltage measurement — standard CE testing per CISPR 16-1-2
  • EMC compliance pre-test and formal test preparation — receiver-protected workflows
  • EMI filter debugging in switched-mode power designs — CM/DM separation for root-cause analysis
  • Common-mode and differential-mode interference analysis — advanced filter characterization
  • Industrial and automotive EMC validation — high-current high-frequency testing

Key Advantages

  • Standards-OrientedDesigned to meet CISPR16-1-2:2006 requirements for V-network conducted emission testing
  • Stable ReferenceProvides consistent impedance for the DUT while isolating unwanted mains interference
  • EMI Debug ReadySelected models support common-mode and differential-mode analysis for filter debugging
  • Receiver ProtectionLimiter-equipped model helps protect sensitive receivers and spectrum analyzers
  • Series FlexibilityCovers standard single-phase, protected, CM/DM, and high-current high-frequency use cases

Performance Highlights

  • ChannelsSingle-phase L/N
  • Power16 A / 100 A models
  • Key Spec9 kHz – 200 MHz
  • TypeV-type LISN

Request a Demo

See the EM5040 Series LISN in action. Our engineers provide 1-on-1 consultations for your specific testing needs.

Get a Quote

Looking for EMC test equipment or a custom LISN solution?

XGY Tek specializes in power-line stabilization and EMC validation setups for conducted emission measurement, EMI debugging, and compliance testing.