The XGY XMU5201A is a four-channel high-precision PXIe source measure unit for four-quadrant voltage sourcing, current sourcing, voltage measurement, current measurement, and electronic-load workflows. It combines 600 kS/s sampling, ±24 V operation, five current ranges through 150 mA, 20 µV voltage resolution, and current resolution down to 10 pA.

Get a Quote Download Datasheet
XMU5201A Four-Channel High-Precision Source Measure Unit

Core Specifications

Compare the model-specific channel count, voltage and current ranges, resolution, sampling rate, and platform details for the XMU5201A Four-Channel High-Precision Source Measure Unit. The detailed table and downloadable datasheet define the applicable conditions for each specification.

Channels

4

Voltage Range

±24 V

Current Sensitivity

Down to 10 pA

Sampling

600 kS/s

Current Range

10 µA / 100 µA / 1 mA / 10 mA / 150 mA

Platform

PXIe 3U, 4 HP

Application fit

Match the product configuration to the engineering workflow before quotation.

Use the application fit, workflow and RFQ sections below to turn a product page into a practical engineering shortlist.

Application fit

Semiconductor Device And Component Testing

XMU5201A Four-Channel High-Precision Source Measure Unit should be scoped around Semiconductor device and component testing, with voltage, power, interface, protection and acceptance requirements confirmed before quotation.

4±24 V10 µA to 150 mA

Application fit

LED And Laser Diode Testing

XMU5201A Four-Channel High-Precision Source Measure Unit should be scoped around LED and laser-diode testing, with voltage, power, interface, protection and acceptance requirements confirmed before quotation.

±24 V10 µA to 150 mA600 kS/s

Application fit

Aerospace Electronics Validation

XMU5201A Four-Channel High-Precision Source Measure Unit should be scoped around Aerospace electronics validation, with voltage, power, interface, protection and acceptance requirements confirmed before quotation.

10 µA to 150 mA600 kS/s±24 V

Application fit

Power Electronics Characterization

XMU5201A Four-Channel High-Precision Source Measure Unit should be scoped around Power-electronics characterization, with voltage, power, interface, protection and acceptance requirements confirmed before quotation.

600 kS/s±24 V20 µV

Application fit

Semiconductor Research

XMU5201A Four-Channel High-Precision Source Measure Unit should be scoped around Semiconductor research, with voltage, power, interface, protection and acceptance requirements confirmed before quotation.

±24 V20 µVDown to 10 pA

Application fit

Materials And Biochemical Research

XMU5201A Four-Channel High-Precision Source Measure Unit should be scoped around Materials and biochemical research, with voltage, power, interface, protection and acceptance requirements confirmed before quotation.

20 µVDown to 10 pA10 µA / 100 µA / 1 mA / 10 mA / 150 mA

Four-Channel Precision Sourcing and Measurement

The XMU5201A is a 3U, 4 HP PXIe source measure unit with four source-and-measure channels and four-quadrant operation. It is designed for semiconductor, optoelectronic, aerospace, power-electronics, materials, and biochemical research workflows that need low-current resolution together with automated modular integration.

The voltage path provides a ±24 V range with 20 µV resolution. Five current ranges extend from 10 µA to 150 mA, with minimum programming and measurement resolution of 10 pA on the 10 µA range. The sampling rate is 600 kS/s.

Voltage Programming and Measurement

RangeResolutionTypical noiseAccuracy at 23 °C ± 5 °C
±24 V20 µV20 µV peak-to-peak±(0.015% + 1.2 mV)

Typical voltage noise is specified from 0.1 Hz to 10 Hz. Accuracy is expressed as a percentage of reading plus the stated offset.

Current Programming and Measurement

RangeResolutionTypical noiseAccuracy at 23 °C ± 5 °C
10 µA10 pA10 pA±(0.025% + 1.5 nA)
100 µA100 pA100 pA±(0.025% + 15 nA)
1 mA1 nA1 nA±(0.025% + 150 nA)
10 mA10 nA10 nA±(0.025% + 1.5 µA)
150 mA150 nA150 nA±(0.025% + 24 µA)

Typical current noise is specified peak-to-peak from 0.1 Hz to 10 Hz. Choose the range that covers the DUT current while preserving the required resolution.

PXIe and Software Integration

The module uses a PXIe bus and a 3U, 4 HP form factor. Software support includes Windows and Linux with a VISA-based DLL. Operating temperature is 0 °C to +55 °C, and storage temperature is -20 °C to +70 °C.

Frequently Asked Questions

How many channels does the XMU5201A provide?

It provides four source-and-measure channels with four-quadrant operation.

What are its voltage and current capabilities?

The voltage range is ±24 V. Current ranges are 10 µA, 100 µA, 1 mA, 10 mA, and 150 mA, with voltage resolution of 20 µV and minimum current resolution of 10 pA.

How does XMU5201A differ from XMU5201B?

Both models provide four channels on the same PXIe range and sampling platform. XMU5201A is the higher-resolution variant; use the XMU5201B page and datasheet when comparing its model-specific resolution and accuracy values.

Which software environments are supported?

The platform supports Windows and Linux with a VISA-based DLL.

Which applications is it intended for?

Application areas include semiconductor and component test, LED and laser-diode test, aerospace and power electronics, semiconductor research, and materials or biochemical research.

Key Advantages

  • Four SMU Channels Four source-and-measure channels provide four-quadrant operation in one 3U, 4 HP PXIe module.
  • 10 pA Minimum Resolution The 10 µA range provides 10 pA programming and measurement resolution.
  • ±24 V Sourcing A ±24 V voltage range combines with 20 µV resolution for precision device characterization.
  • Five Current Ranges Select 10 µA, 100 µA, 1 mA, 10 mA, or 150 mA to match the DUT and measurement objective.
  • 600 kS/s Sampling The 600 kS/s sampling rate supports automated characterization and transient-oriented test workflows.
  • PXIe Automation Windows and Linux support with a VISA-based DLL integrates the module into modular test systems.

Performance Highlights

  • Channels 4
  • Voltage Range ±24 V
  • Current Range 10 µA to 150 mA
  • Sampling 600 kS/s

Configure an SMU for your device test

Send the DUT type, source and measurement ranges, compliance limits, channel count, pulse or sweep timing, fixture details, and required acceptance evidence.

Get a Quote

Product Specifications

Parameter Specification
Channels 4
Operation Four-quadrant source/measure
Voltage Range ±24 V
Voltage Resolution 20 µV
Current Sensitivity Down to 10 pA
Current Range 10 µA / 100 µA / 1 mA / 10 mA / 150 mA
Sampling 600 kS/s
Platform PXIe 3U, 4 HP
Operating Temperature 0 °C to +55 °C
Storage Temperature -20 °C to +70 °C
Operating Systems Windows and Linux
Driver Interface VISA-based DLL

* Specifications are subject to change without notice. Contact XGY Tek for the full technical datasheet.

Technical Resources

Download Datasheet

PDF technical specifications

Get a Quote

Pre-filled product inquiry

Fit check

Use this product when the requirement matches the published envelope.

Strong fit

  • Projects centred on Semiconductor device and component testing
  • Projects centred on LED and laser-diode testing
  • Projects centred on Aerospace electronics validation
  • Requirements that benefit from Four SMU Channels and 10 pA Minimum Resolution

Review alternatives

  • Requirements outside the published voltage, current, power or frequency envelope
  • Projects without a defined DUT, site power, interface or acceptance method
  • Simple bench work where a lower-cost standard supply would meet the requirement
  • RFQs that cannot yet specify protection, cooling, cabling or control boundaries

Quote-stage checklist

The fastest way to make the enquiry useful.

Voltage rangeCurrent / powerOperating modeDUT typeLoad profileControl interfaceProtection needsCooling / installationCable / fixture planCompliance workflowLead timeFAT/SAT evidence

Add the operating profile, safety boundary, control interface and acceptance evidence expected by the buyer before requesting final configuration and lead time.

Quote workflow

Make the test plan visible before the quote is final.

A useful RFQ is a short engineering model: operating envelope, DUT workflow, control boundary and acceptance evidence.

Send RFQ
01

Confirm the electrical envelope

Ratings map

Start with ±24 V. Confirm the required model rating before treating the page summary as a released configuration.

02

Define the DUT workflow

Use-case brief

Map the equipment to Semiconductor device and component testing; LED and laser-diode testing; Aerospace electronics validation and record any transient, cycling, compliance or automation needs.

03

Lock the acceptance package

Quote evidence

Confirm VISA-based DLL, protection requirements, data logging, remote control and the FAT/SAT evidence needed by the buyer.

Frequently Asked Questions

What should buyers know about XMU5201A Four-Channel High-Precision Source Measure Unit?

This product page summarises XMU5201A Four-Channel High-Precision Source Measure Unit within XGY Tek's Source Measure Units catalogue. Review the published specifications and application notes to determine whether the product matches the intended workflow.

Which published specifications should buyers compare for XMU5201A Four-Channel High-Precision Source Measure Unit?

Start with the values highlighted on this page: Channels: 4; Operation: Four-quadrant source/measure; Voltage Range: ±24 V; Voltage Resolution: 20 µV. Check whichever selection criteria apply, such as measurement or operating range, resolution, accuracy, sensitivity, interfaces, software compatibility, environmental limits, accessories, and any stated test conditions. Not every criterion applies to every product.

How should XMU5201A Four-Channel High-Precision Source Measure Unit be matched to an application?

Published applications include Semiconductor device and component testing; LED and laser-diode testing; Aerospace electronics validation; Power-electronics characterization; Semiconductor research. Use the application notes as selection guidance, then confirm the required operating conditions, interfaces, software compatibility, and accessories against the published specifications.

When should buyers compare another option in Source Measure Units?

Compare alternatives when the published measurement or operating range, resolution, accuracy, sensitivity, interfaces, software compatibility, environmental limits, or available accessories do not match the intended workflow. Confirm any critical value together with its stated conditions before selecting a configuration.

How can I request a quote or datasheet for XMU5201A Four-Channel High-Precision Source Measure Unit?

Use the Get a Quote form to share the application, required configuration, interfaces, accessories, documentation needs, and timing. XGY Tek will review the request before confirming a suitable configuration. A downloadable datasheet is linked from the product page.Get a Quote