Network Analyzers
YNA-510 Series Vector Network Analyzer
Frequency range 100 kHz to 14 GHz / 20 GHz / 26.5 GHz; 10 MHz to 43.5 GHz / 67 GHz by model
XGY YNA-510 is a vector network analyzer family for measuring amplitude, phase and group delay of microwave networks in radar, communication, navigation, defense and university research.
- Frequency Range
- 100kHz~14GHz / 100kHz~20GHz / 100kHz~26.5GHz / 10MHz ~40/43.5GHz / 10MHz~67GHz By model: -14G / -20G / -26G5 / -43G5 / -67G. The -43G5-210 and -43G5-410 configurations cover 40 GHz.
- Test Ports
- 2/4
- IF Bandwidth
- 1Hz ~ 30MHz,1, 2, 3, 5, 7 steps
- Weight
- 24 kg / 26 kg / 30 kg By model: 24 kg for -14G / -20G / -26G5; 26 kg for -43G5; 30 kg for -67G.
YNA-510 Series overview
Product Overview
It can accurately measure the amplitude frequency characteristics and phase frequency characteristics and group delay characteristics of microwave network. YNA-510 series vector network analyzers retain the features of high-end vector network analyzers, including performance indicators, instrument appearance, display effect, software interface, etc., while controlling the volume, weight, wind noise and other aspects of the instrument to create a good experience for users. The product can be widely used in radar, communication, navigation and other fields, which are indispensable test equipment in national defense military industry and university scientific research.
YNA-510 series vector network analyzers include YNA-510-14G (100 kHz~14GHz), YNA-510-20G (100 kHz~20GHz), YNA-510-26G5 (100 kHz~26.5GHz), YNA-510-43G5 (10MHz~43.5GHz) and YNA-510-67G (10MHz ~67GHz), 2 ports or 4 ports.
YNA-510 series network analyzer provides frequency response, Single-port, response isolation, enhanced response, full-dual port, electronic calibration etc. Offer various display formats, such as logarithmic amplitude, linear amplitude, phase, group delay, Smith chart and polar coordinates. It designed with several standard interfaces, such as: USB, LAN, GPIB, VGA, and HDMI interface.
It can accurately measure the amplitude frequency characteristics and phase frequency characteristics and group delay characteristics of microwave network. YNA-510 series vector network analyzers retain the features of high-end vector network analyzers, including performance indicators, instrument appearance, display effect, software interface, etc., while controlling the volume, weight, wind noise and other aspects of the instrument to create a good experience for users. The product can be widely used in radar, communication, navigation and other fields, which are indispensable test equipment in national defense military industry and university scientific research.
Main Characteristics
- Wider frequency coverage, starting frequency as low as 100 kHz
- More optional intermediate frequency bandwidth, the maximum intermediate frequency bandwidth is up to 30MHz
- Advanced calibration technology, vivid wizard calibration, flexible calibration type, compatible with multiple calibration kits
- Offer various display formats, such as logarithmic amplitude, linear amplitude, SWR, group delay, Smith chart and polar coordinates
- Chinese/English operation interface, 12.1 -inch 1280*800 high-resolution multi-touch screen
- Recording/replay, one-button operation simplifies the measurement
- Easy to operation by advanced time domain options with added TDR impedance measurement, eye diagram analysis functions
Large dynamic range
The YNA-510 series vector network analyzer are designed with concept of fundamental wave mixing receiver, which effectively expands the test dynamic range of the complete machine and the test demand for large dynamic range.
Time Domain Analysis Option
English-localized UI illustration.
The YNA-510 series vector network analyzer can realize the switching of the measurement results between the frequency-domain and the time-domain which can be used to identify the discontinuous points of devices, fixtures or cables to realize accurate fault location.
Improve the scanning speed tremendously
The YNA-510 series vector network analyzer has a scanning speed of up to 43ms under the condition of all-frequency with 201 point scanning and 600 kHz medium frequency bandwidth, and provides single key scanning time test function for easy evaluation.
Multiple windows to display all measuring channels
The analyzer features functions of multi-channel and multi-window display, support up to 64 channels, maximum 32 measuring windows can be simultaneously displayed, and each window can simultaneously display up to 16 test traces, which makes the observation result more visible and the operation more convenient.
Intuitive user interface for easy operation, which can improve test efficiency
Front-panel illustration; refer to the specification tables for performance limits.
The soft panel can be set to the left or right side of screen, or be hidden.
Parameters can be entered quickly by using the activated input toolbar. Set limit line and segment scan value for production line to improve test efficiency.
Flexible calibration type, compatible with multiple calibration kits
YNA-510 series vector network analyzer provides different types of calibration such as automated calibration, guided calibration (through response calibration, through response and isolation, single port calibration, enhanced response calibration, full two-port SOLT calibration, TRL calibration can be achieve by mechanical calibration kits), electrical calibration (ECal) etc. Users can choose calibration types based on the test requirements, which greatly facilitates testing on devices with different interfaces.
Recording function achieved single key by automated testing
Record all the operation steps in the process of using the instrument. At the same time, the dialog box for editing can be inserted at any time, and the dialog box will pop up on time to wait for confirmation, so as to realize the interactive function and achieve the single key automation function of the intelligent instrument.
Advanced Time Domain Analysis Option
With the rapid development of the information industry, the requirement for network bandwidth is also higher, which requires information equipment (such as large servers, computers and switches, etc.) to be able to carry faster data rates. Information equipment manufacturers pay more attention on the problem of signal integrity in high-speed interconnection channels. The characteristic changes of transmission links will significantly affect the signal transmission quality. Advanced time domain analysis is an important means to evaluate the signal transmission quality of high-speed links.
TDR time domain impedance test can test the impedance characteristic changes on the transmission line accurately and locate discontinuity.
Advanced Time Domain Analysis Option
English-localized UI illustration.
Convenient near-end and far-end crosstalk testing allows simultaneous analysis of time-domain and frequency-domain data to test the degree of interaction between multiple transmission lines.
Advanced Time Domain Analysis Option
The advanced time domain analysis option of YNA-510 series vector network provides virtual eye pattern and analysis function based on S parameter. The output unit of the simulation code type is used to generate the data bits of 0 and 1 change, convolve the simulation code type with the time-domain impulse response of the tested part, and obtain the virtual eye map after superposition.
Depending on the different high speed digital communication standards, TDR options can be used for high efficiency Pass/Fail tests using predefined eye pattern templates.
Advanced Time Domain Analysis Option
The advanced time domain analysis option can apply Jitter, noise and other interference on the simulation eye pattern, and simulate the simulation eye pattern at different positions of high-speed link in real environment by adding correction algorithms such as pre-weighting and equalization.
Automatic fixture removal option
The measurement objects of vector network analyzer involve non-standard connector devices, such as encapsulated microwave devices, on-chip devices, etc. The most remarkable feature of such devices is that they cannot be directly connected to the vector network analyzer. The fixture can be connected to the vector network analyzer, but the fixture error is also introduced. The automatic fixture removal function can extract, store and embed the fixture parameters to obtain the real parameters of the tested part. It is easy to operate and has high precision.
The single-end fixture and differential fixture can be set, and the port number of the fixture can also be selected during the process of describing fixture. To extract fixture parameters, the fixture standards need to be measured. In the standard description interface, fixture standard includes three types: straight through standard, open standard, and short circuit standard.
The automatic fixture removal function is used to extract the balance parameters of the tested parts and embed the four ports. The test results show that the transfer parameters can be removed; the near-end and far-end crosstalk also can be removed well.
Automatic fixture removal option
English-localized UI illustration.
Automatic fixture removal option
English-localized UI illustration.
Key figures
- Freq. Resolution
- 0.1Hz
- Max Sweep Points
- 200001
- System Impedance
- 50Ω
YNA-510 Series capabilities and applications
YNA-510 Series applications
-
Radar, communication and navigation component test
-
Defense and university research
-
Signal integrity of high-speed interconnects
With the TDR option, impedance changes along a transmission line are measured and discontinuities located, for servers, computers and switches that carry faster data rates.
-
Near-end and far-end crosstalk testing
Time-domain and frequency-domain data are analyzed together to test the interaction between multiple transmission lines.
-
Fixtured and on-chip device measurement
The automatic fixture removal option extracts, stores and embeds fixture parameters for encapsulated microwave devices and on-chip devices that cannot connect directly.
-
Fault location in devices, fixtures and cables
Automatic fixture removal option
Application illustration; not a measurement of product performance.
Application images show typical use settings; they do not indicate measured performance.
YNA-510 Series specifications
Full specification table — 13 published parameters
| Parameter | Specification |
|---|---|
| Technical Specifications | |
| Port Number | 2/4 |
| Freq. Resolution | 0.1Hz |
| Freq. Accuracy | ±1×10⁻⁷(23℃±3℃) |
| IF bandwidth | 1Hz ~ 30MHz,1, 2, 3, 5, 7 steps |
| Max Sweep Points | 200001 |
| Port Connectors | YNA-510-14G, YNA-510-20G: 3.5mm NMD( m); YNA-510-26G5: 2.4 mm NMD(m); YNA-510-67G: 1.85 mm NMD(m) By model Models: YNA-510-14GYNA-510-20GYNA-510-26G5YNA-510-67G |
| System Impedance | 50Ω |
| External interfaces | USB, GPIB, VGA, LAN, HDMI |
| Displaying types | 12.1”16:10 LCD (Capacitive multi-touch LCD) |
| Displaying windows and channels | Up to 32 windows and 64 channels can be set up, with each window having up to 16 selectable data tables. |
| Dimension (W*H*D) | YNA-510-14G / YNA-510-20G / YNA-510-26G5 :(516±4)mm×(279±2.5)mm×(493±4)mm; YNA-510-43G5 (2-port) :(516±4)mm×(279±2.5 )mm×(493±4)mm; YNA-510-43G5(4-port):(516±4)mm×(279±2.5)mm×(543±4)mm; YNA-510-67G:(474±4)mm×(280±2.5 )mm×(533±4)mm; By model |
| Weight (kg) | YNA-510-14G / YNA-510-20G / YNA-510-26G5: 24kg; YNA-510-43G5: 26kg; YNA-510-67G:30kg By model |
| Power Supply | 100VAC ~240VAC, 50Hz/60Hz (adaptive), maximum power consumption 400W |
Detailed specification tables (6)
| YNA-510-14G | YNA-510-20G | YNA-510-26G5 | YNA-510-43G5 | YNA-510-67G | |
|---|---|---|---|---|---|
| Freq. Range | 100kHz~14GHz | 100kHz~20GHz | 100kHz~26.5GHz | 10MHz ~40/43.5GHz | 10MHz~67GHz |
| YNA-510-14G YNA-510-20G YNA-510-26G5 — 2 ports | YNA-510-14G YNA-510-20G YNA-510-26G5 — 4 ports | YNA-510-43G5 — Standard configuration, 400 option(43.5GHz) | YNA-510-43G5 — 210, 410 options (40GHz) | YNA-510-67G — 2/4 ports | |
|---|---|---|---|---|---|
| Max Output Power | +5dBm(100kHz~10MHz) +15dBm(10MHz~4GHz) +15dBm(4GHz~10GHz) +10dBm(10GHz~14GHz) +9dBm(14GHz~20GHz) +6dBm(20GHz~24GHz) +2dBm(24GHz~26.5GHz) | +3dBm(100kHz~10MHz) +13dBm(10MHz~4GHz) +10dBm(4GHz~10GHz) +4dBm(10GHz~14GHz) +3dBm(14GHz~20GHz) -2dBm(20GHz~24GHz) -4dBm(24GHz~26.5GHz) | +12dBm(10MHz~50MHz) +13dBm(50MHz~250MHz) +13dBm(250MHz~1GHz) +13dBm(1GHz~10GHz) +10dBm(10GHz~20GHz) +8dBm(20GHz~35GHz) +3dBm(35GHz~43.5GHz) | +10dBm(10MHz~50MHz) +13dBm(50MHz~250MHz) +13dBm(250MHz~1GHz) +13dBm(1GHz~10GHz) +10dBm(10GHz~20GHz) +6dBm(20GHz~35GHz) +3dBm(35GHz~40GHz) | +12dBm(10MHz~50MHz) +13dBm(50MHz~250MHz) +13dBm(250MHz~1GHz) +13dBm(1GHz~10GHz) +10dBm(10GHz~40GHz) +10dBm(40GHz~60GHz) +8dBm(60GHz~67GHz) |
| YNA-510-14G YNA-510-20G YNA-510-26G5 | YNA-510-43G5 | YNA-510-67G | |
|---|---|---|---|
| Min Output Power (Typical) | -60dBm | -60dBm | -50dBm |
| Power Sweep Range | ≥60dB | ≥63dB | ≥55dB |
| YNA-510-14G YNA-510-20G YNA-510-26G5 — 2 ports | YNA-510-14G YNA-510-20G YNA-510-26G5 — 4 ports | YNA-510-43G5 — Standard configuration, 400 option(43.5GHz) | YNA-510-43G5 — 210, 410 options (40GHz) | YNA-510-67G — 2/4 ports | |
|---|---|---|---|---|---|
| System Dynamic Range (10Hz IF bandwidth) | 102dB(100kHz~10MHz) 132dB(10MHz~4GHz) 133dB(4GHz~10GHz) 125dB(10GHz~14GHz) 124dB(14GHz~20GHz) 120dB(20GHz~24GHz) 115dB(24GHz~26.5GHz) | 102dB(100kHz~10MHz) 132dB(10MHz~4GHz) 130dB(4GHz~10GHz) 120dB(10GHz~14GHz) 119dB(14GHz~20GHz) 115dB(20GHz~24GHz) 110dB(24GHz~26.5GHz) | 90dB(10MHz~50MHz) 98dB(50MHz~250MHz) 115dB(250MHz~1GHz) 128dB(1GHz~10GHz) 122dB(10GHz~20GHz) 118dB(20GHz~35GHz) 110dB(35GHz~43.5GHz) | 120dB(10MHz~50MHz) 120dB(50MHz~250MHz) 125dB(250MHz~1GHz) 128dB(1GHz~10GHz) 122dB(10GHz~20GHz) 113dB(20GHz~35GHz) 108dB(35GHz~40GHz) | 90dB(10MHz~50MHz) 98dB(50MHz~250MHz) 115dB(250MHz~1GHz) 128dB(1GHz~10GHz) 122dB(10GHz~20GHz) 118dB(20GHz~50GHz) 110dB(50GHz~67GHz) |
| YNA-510-14G YNA-510-20G YNA-510-26G5 | YNA-510-43G5 | YNA-510-67G | |
|---|---|---|---|
| Effective Directivity | 48dB (100kHz~2GHz) 44dB (2GHz~20GHz) 44dB (20GHz~26.5GHz) | 42dB (10MHz~2GHz) 45dB (2GHz~20GHz) 38dB (20GHz~43.5GHz) | 35dB (10MHz~2GHz) 40dB (2GHz~50GHz) 35dB(50GHz~67GHz) |
| Effective Source Match | 40dB(100kHz~2GHz) 30dB(2GHz~20GHz) 30dB(20GHz~26.5GHz) | 40dB(10MHz~2GHz) 30dB(2GHz~20GHz) 30dB(20GHz~43.5GHz) | 34dB(10MHz~2GHz) 28dB(2GHz~50GHz) 27dB(50GHz~67GHz) |
| Effective Load Match | 48dB(100kHz~2GHz) 44dB(2GHz~20GHz) 44dB(20GHz~26.5GHz) | 42dB(10MHz~2GHz) 45dB(2GHz~20GHz) 36dB(20GHz~43.5GHz) | 35dB(10MHz~2GHz) 36dB(2GHz~50GHz) 33dB(50GHz-67GHz) |
| YNA-510-14G YNA-510-20G YNA-510-26G5 | YNA-510-43G5 | YNA-510-67G | |
|---|---|---|---|
| Amplitude Tracking noise (-5dBm, 1kHz IF bandwidth) | 0.010dB rms(100kHz~50MHz) 0.005dB rms(50MHz~500MHz) 0.001dB rms(500MHz~14GHz) 0.001dB rms(14GHz~20GHz) 0.002dB rms(20GHz~26.5GHz) | 0.1000dB rms(10MHz~50MHz) 0.0200dB rms(50MHz~100MHz) 0.0200dB rms(100MHz~500MHz) 0.0030dB rms(500MHz~26.5GHz) 0.0030dB rms(26.5GHz~43.5GHz) | 0.0500dB rms (10MHz~50MHz) 0.0030dB rms (50MHz~500MHz) 0.0020dB rms (500MHz~26.5GHz) 0.0030dB rms (26.5GHz~50GHz) 0.0090dB rms (50GHz~67GHz) |
| Phase Tracking noise (-5dBm, 1kHz IF bandwidth, Transmission) | 0.100° rms(100kHz~50MHz) 0.040° rms(50MHz~500MHz) 0.030° rms(500MHz~14GHz) 0.040° rms(14GHz~20GHz) 0.040° rms(20GHz~26.5GHz) | 1.000° rms(10MHz~50MHz) 1.000° rms(50MHz~100MHz) 0.500° rms(100MHz~500MHz) 0.020° rms(500MHz~26.5GHz) 0.030° rms(26.5GHz~43.5GHz) | 0.400° rms (10MHz~50MHz) 0.020° rms (50MHz~500MHz) 0.020° rms (500MHz~26.5GHz) 0.030° rms (26.5GHz~50GHz) 0.040° rms (50GHz~67GHz) |
Product and technical media
Large dynamic range
Technical plot.
Front panel and user interface
Technical diagram. Front-panel illustration; refer to the specification tables for performance limits.
Advanced Time Domain Analysis Option
Technical plot.
Advanced Time Domain Analysis Option
Technical plot.
More figures (3)
Advanced Time Domain Analysis Option
Technical plot.
Advanced Time Domain Analysis Option
Technical plot.
Advanced Time Domain Analysis Option
Technical plot.
YNA-510 Series models, configuration and compatibility
| Model | Frequency range | Port connection | Weight |
|---|---|---|---|
| YNA-510-14G | 100kHz~14GHz | 3.5mm NMD( m) | 24kg |
| YNA-510-20G | 100kHz~20GHz | 3.5mm NMD( m) | 24kg |
| YNA-510-26G5 | 100kHz~26.5GHz | 2.4 mm NMD(m) | 24kg |
| YNA-510-43G5 | 10MHz ~40/43.5GHz | — | 26kg |
| YNA-510-67G | 10MHz~67GHz | 1.85 mm NMD(m) | 30kg |
Model comparison tables (1)
Model comparison
| Main Units | Description |
|---|---|
| YNA-510-14G | Vector Network Analyzer(100kHz~14GHz) |
| YNA-510-20G | Vector Network Analyzer(100kHz~20GHz) |
| YNA-510-26G5 | Vector Network Analyzer(100kHz~26.5GHz) |
| YNA-510-43G5 | Vector Network Analyzer(10MHz~43.5GHz) |
| YNA-510-67G | Vector Network Analyzer(10MHz~67GHz) |
Options
Options (44)
| Code | Description | Models | Standard | Requires / excludes |
|---|---|---|---|---|
| YNA-510-006 | English Option | Not stated | Optional | Description: Configure the English front and rear panels and The English operating system |
| YNA-510-011 | 31101 N-type 50ΩCalibration Kit | Not stated | Optional | Description: For Calibration of the Analyzer(DC~18GHz) |
| YNA-510-013 | 31121 3.5mm Calibration Kit | Not stated | Optional | Description: For Calibration of the Analyzer(DC~26.5GHz) |
| YNA-510-014 | 20202 3.5mm Calibration Kit | Not stated | Optional | Description: For Calibration of the Analyzer(DC~9GHz) |
| YNA-510-016 | 31123A 2.4mm Calibration Kit | Not stated | Optional | Description: For Calibration of the Analyzer(DC~50GHz) |
| YNA-510-017 | 20209FB 2.92mm Calibration Kit | Not stated | Optional | Description: For Calibration of the Analyzer(DC~40GHz) |
| YNA-510-025 | 87302AZ N/N-JJ cable | Not stated | Optional | Description: Type N(male) to Type N(male), 60cm long |
| YNA-510-026 | 87302BA N/N-KJ cable | Not stated | Optional | Description: Type N(male) to Type N(femal), 60cm long |
| YNA-510-027 | 87302SR,2.92/2.92-KJ cable | Not stated | Optional | Description: 2.92mm (male) to 2.92mm N(male), 60cm long, Flexible cable, economical |
| YNA-510-028 | 87302SS,2.92/2.92-KK cable | Not stated | Optional | Description: 2.92mm (femal) to 2.92mm N(female), 60cm long, Flexible cable, economical |
| YNA-510-029 | 87308SR,NMD2.92/2.92-KJ cable | Not stated | Optional | Description: 2.92mm NMD to 2.92mm N(male), 63cm long, Phase- and amplitude-stable cable |
| YNA-510-030 | 87308SS,NMD2.92/2.92-KK cable | Not stated | Optional | Description: 2.92mm NMD to 2.92mm N(female), 63cm long, Phase- and amplitude-stable cable |
| YNA-510-031 | FB0HA0HB025.0 3.5mm Test Cable | YNA-510-14G to YNA-510-26G5 | Optional | Description: For Measurement of the Analyzer(3.5mm Male) Used for YNA-510-14G / YNA-510-20G / YNA-510-26G5 |
| YNA-510-032 | FB0HA0HC025.0 3.5mm Test Cable | YNA-510-14G to YNA-510-26G5 | Optional | Description: For Measurement of the Analyzer(3.5mm Female) Used for YNA-510-14G / YNA-510-20G / YNA-510-26G5 |
| YNA-510-035 | 3671N35M 3.5mm Test Cable | YNA-510-14G to YNA-510-26G5 | Optional | Description: For Measurement of the Analyzer(3.5mm-Male) Length=63cm, Used for YNA-510-14G / YNA-510-20G / YNA-510-26G5 |
| YNA-510-036 | 3671N35F 3.5mm Test Cable | YNA-510-14G to YNA-510-26G5 | Optional | Description: For Measurement of the Analyzer(3.5mm-Female) Length=63cm, Used for YNA-510-14G / YNA-510-20G / YNA-510-26G5 |
| YNA-510-041 | 3671NNF 3.5mm-N Test Cable | YNA-510-14G to YNA-510-26G5 | Optional | Description: For Measurement of the Analyzer(N-Male) Length=63cm, Used for YNA-510-14G / YNA-510-20G / YNA-510-26G5 |
| YNA-510-042 | 3671NNM 3.5mm-N Test Cable | YNA-510-14G to YNA-510-26G5 | Optional | Description: For Measurement of the Analyzer(N-Female) Length=63cm, Used for YNA-510-14G / YNA-510-20G / YNA-510-26G5 |
| YNA-510-047 | FE0BN0BM025.0 2.4mm Gore Test Cable | YNA-510-43G5 | Optional | Description: For Measurement of the Analyzer(2.4mm-Male) Used for YNA-510-43G5 |
| YNA-510-048 | FE0BN0BL025.0 2.4mm Gore Test Cable | YNA-510-43G5 | Optional | Description: For Measurement of the Analyzer(2.4mm-Female) Used for YNA-510-43G5 |
| YNA-510-062 | Cabinet Option | Not stated | Optional | — |
| YNA-510-070 | High-Performance Computing Option | Not stated | Optional | Description: Designed for data-intensive applications such as automated test systems and advanced time-domain analysis, this option enhances data throughput efficiency. |
| YNA-510-S05 | S-Parameter Signal Integrity Analysis | Not stated | Optional | Description: Used to analyze signal integrity characteristics—such as frequency-domain response, time-domain TDR, and crosstalk— and capable of automatically converting plotted curves into test reports. |
| YNA-510-S07 | AFR automatic fixture remove option | Not stated | Optional | Description: Used for automatic test and removal of single end and balance device measuring fixture |
| YNA-510-S10 | Time-domain measurements | Not stated | Optional | Description: Used for time domain measurements to determine and analyze discontinuous locations in devices, fixtures or cables |
| YNA-510-S11 | Advanced Time-domain measurements | Not stated | Optional | Description: Used for TDR time domain impedance test, eye chart analysis, etc. |
| YNA-510-S17 | Test Data Management Software | Not stated | Optional | Description: Enables automatic saving and management of test data, as well as the generation of data reports. |
| YNA-510-S18 | Rapid Continuous Wave (CW) Scanning | Not stated | Optional | Description: Designed for scenarios requiring efficient, high -volume data storage during automated testing. |
| YNA-510-14G-400 | Four-port Measurement | YNA-510-14G | Optional | Description: Four port VNA (100kHz to 14GHz) |
| YNA-510-20G-400 | Four-port Measurement | YNA-510-20G | Optional | Description: Four port VNA (100kHz to 20GHz) |
| YNA-510-26G5-400 | Four-port Measurement | YNA-510-26G5 | Optional | Description: Four port VNA (100kHz to 26.5GHz) |
| YNA-510-43G5-400 | Four-port Measurement | YNA-510-43G5 | Optional | Description: Four port VNA (10MHz to 43.5GHz) |
| YNA-510-43G5-210 | 40GHz 2-port option | YNA-510-43G5 | Optional | Description: 10MHz to 40GHz 2-port configuration, with improved dynamic range in low frequencies. |
| YNA-510-43G5-410 | 40GHz 4-port option | YNA-510-43G5 | Optional | Description: 10MHz to 40GHz 4-port configuration, with improved dynamic range in low frequencies. |
| YNA-510-67G-400 | Four-port Measurement | YNA-510-67G | Optional | Description: Four port VNA (10MHz to 67GHz) |
| YNA-510-14G-EWT1 | Extended warranty for 1 year | YNA-510-14G | Optional | Description: Extend the warranty period, the warranty is extended for 1 year, and the two-year extended warranty is optional for 2 items, and so on. |
| YNA-510-20G-EWT1 | Extended warranty for 1 year | YNA-510-20G | Optional | Description: Extend the warranty period, the warranty is extended for 1 year, and the two-year extended warranty is optional for 2 items, and so on. |
| YNA-510-26G5-EWT1 | Extended warranty for 1 year | YNA-510-26G5 | Optional | Description: Extend the warranty period, the warranty is extended for 1 year, and the two-year extended warranty is optional for 2 items, and so on. |
| YNA-510-43G5-EWT1 | Extended warranty for 1 year | YNA-510-43G5 | Optional | Description: Extend the warranty period, the warranty is extended for 1 year, and the two-year extended warranty is optional for 2 items, and so on. |
| YNA-510-67G-EWT1 | Extended warranty for 1 year | YNA-510-67G | Optional | Description: Extend the warranty period, the warranty is extended for 1 year, and the two-year extended warranty is optional for 2 items, and so on. |
| YNA-510-14G-JL | Professional calibration services | YNA-510-14G | Optional | Description: Provide metrological calibration services and provide metrological reports |
| YNA-510-20G-JL | Professional calibration services | YNA-510-20G | Optional | Description: Provide metrological calibration services and provide metrological reports |
| YNA-510-26G5-JL | Professional calibration services | YNA-510-26G5 | Optional | Description: Provide metrological calibration services and provide metrological reports |
| YNA-510-43G5-JL | Professional calibration services | YNA-510-43G5 | Optional | Description: Provide metrological calibration services and provide metrological reports |
Standard delivery contents
- Power Cord Assembly (×1)
- USB mouse (×1)
- User Manual (×1)
- Certificate of Conformity (×1)
- Aluminum packing case (×1)
Accessories
Accessories (16)
| Code | Description | Models | Note |
|---|---|---|---|
| 20402D | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (100 kHz ~ 18 GHz,N Type, 2 port) |
| 20402E | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10MHz~26.5GHz,3.5mm 2-port) |
| 20402F | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10 MHz ~ 40 GHz,2.92 mm 2-port) |
| 20402H | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10 MHz to 50 GHz,2.4 mm 2-port) |
| 20402L | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10 MHz to 67 GHz, 1.85mm 2-port) |
| 20404D | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (100 kHz ~ 18 GHz,N Type, 4 port) |
| 20404E | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10MHz~26.5GHz,3.5mm 4-port) |
| 20404F | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10 MHz ~ 40 GHz,2.92 mm 4-port) |
| 20404H | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10 MHz to 50 GHz,2.4 mm 4-port) |
| 20404L | Electronic calibration kit | Not stated | YNA-510 series General Options; For VNA calibration (10 MHz to 67 GHz, 1.85mm 4-port) |
| FF0CN0CM025.0 | 1.85mm Gore test cable | YNA-510-67G | YNA-510 series General Options; Phase Stable Cable, NMD to 1.85mm(Male), Suitable for YNA-510-67G |
| FF0CN0CL025.0 | 1.85mm Gore test cable | YNA-510-67G | YNA-510 series General Options; Phase Stable Cable, NMD to 1.85mm(female), Suitable for YNA-510-67G |
| 87302NN | 1.85mm test cable | YNA-510-67G | YNA-510 series General Options; Phase Stable Cable, NMD to 1.85mm(Male), Suitable for YNA-510-67G |
| 87302NM | 1.85mm test cable | YNA-510-67G | YNA-510 series General Options; Phase Stable Cable, NMD to 1.85mm(female), Suitable for YNA-510-67G |
| 87302NZ | 1.85mm flexible cable | Not stated | YNA-510 series General Options; 1.85mm flexible cable, 1.85mm(female) to 1.85mm(female) |
| 87302NY | 1.85mm flexible cable | Not stated | YNA-510 series General Options; 1.85mm flexible cable, 1.85mm(male) to 1.85mm(female) |
YNA-510 Series selection guidance
- Format
- Benchtop analyzer with 12.1-inch touch screen; 2 or 4 measuring ports
- Coverage
- Frequency range 100 kHz to 14 GHz / 20 GHz / 26.5 GHz by model; 10 MHz to 43.5 GHz / 67 GHz by model
- Best for
- Microwave component characterization in radar, communication and navigation labs, including signal-integrity work with time-domain options.
YNA-510 Series technical resources
Request a quote for the YNA-510 Series
Share the application, required configuration and documentation needs for the YNA-510 Series, or compare it with other products in the Network Analyzers category first. XGY Tek reviews each request and confirms model, options and delivery documentation in the quotation.