Frequency range 10 MHz to 26.5 GHz / 10 MHz to 44 GHz / 10 MHz to 67 GHz by model

XGY YNA-720 Series is a vector network analyzer for semiconductor chip, material, antenna, high-speed cable and microwave component testing, with a frequency range of 10 MHz to 26.5 GHz / 10 MHz to 44 GHz / 10 MHz to 67 GHz by model. Several measurement functions run through one connection.

YNA-720 Series Vector Network Analyzer
Frequency Range
10 MHz to 26.5 GHz / 10 MHz to 44 GHz / 10 MHz to 67 GHz By model: -26G5 / -44G / -67G
Test Ports
2 standard; 4 optional 4 ports with the four-port measurement option (-400)
IF Bandwidth
1 Hz to 30 MHz
Weight
50 kg Maximum

YNA-720 Series overview

The YNA-720 Series is a vector network analyzer platform for semiconductor chip, material, antenna, high-speed cable and microwave component testing. Its three models, the YNA-720-26G5, YNA-720-44G and YNA-720-67G, differ in frequency range and port connector: frequency range is 10 MHz to 26.5 GHz / 10 MHz to 44 GHz / 10 MHz to 67 GHz by model, and the port connectors are 3.5 mm, 2.4 mm and 1.85 mm respectively, each with a 50 Ω system impedance.

Flexible hardware configuration and measurement software combine several measurement tasks through one connection. The platform provides 21 measurement functions, among them pulse S-parameter, frequency-conversion, gain-compression, spectrum, signal-integrity, differential I/Q and total harmonic distortion measurements, and the available functions depend on the configured hardware and measurement options. IF bandwidth is selectable from 1 Hz to 30 MHz, and a sweep holds 200,001 measurement points.

A 15.6-inch multitouch display presents multiple parameters on one screen, and SCPI instruction synchronization recording generates a script with one key. The detachable CPU module carries the hard disk and the LAN, DP, USB and GPIB interfaces. The rear panel adds a 10 MHz reference input and output, pulse and trigger inputs and outputs, a bias-tee configuration input and an automatic test interface for integration into a test rack.

Key figures

Measurement points
200,001
Stated for the series
Display
15.6-inch high-resolution touch display
Measured ports
2 ports standard

YNA-720 Series capabilities and applications

Detailed features and capabilities

Measurements and calibration

The YNA-720 Series measures S-parameters, differential (balanced) parameters and receiver quantities, and runs limit, ripple and filter bandwidth tests. Display formats include logarithmic magnitude, phase, group delay, Smith chart, linear magnitude, VSWR, real part, imaginary part, polar coordinates and impedance.

Pulse S-parameter measurement

A built-in 4-channel pulse generator handles internal source modulation, IF gate control and output from the rear panel. Automatic broadband synchronous measurement, narrow-band asynchronous measurement and an adaptive narrow-band filter support narrow-pulse tests, and three trigger input and output modules coordinate the analyzer with other instruments.

Frequency-converter and active-device measurement

Noise figure measurement is option -003, listed for YNA-720-26G5 to YNA-720-67G.

Mixer and converter scalar measurement supports linear, power and segment sweeps, power-meter calibration across the RF and IF bands, and dual independent source power and receiver calibration for non-insertable devices. Vector measurement adds amplitude response, absolute phase and absolute delay in a single connection. Noise figure measurement uses the cold-source method and patented noise embedding and de-embedding for devices with non-standard interfaces, and reports the minimum noise figure, the noise internal resistance and the optimal reflection coefficient. FFT-based spectrum analysis on each port locates spurious signals and harmonics, with in-band power, power spectral density, occupied bandwidth and adjacent power ratio markers.

Signal integrity, harmonic distortion and fixture removal

Signal-integrity analysis provides micron-level spatial resolution for small chip packages and tests near-end and far-end crosstalk between transmission lines. Simulated eye diagrams accept jitter, noise, pre-emphasis and equalization. Total harmonic distortion measurement under true differential excitation corrects ratio, absolute receiver and port excitation power errors with a single calibration. Automatic fixture removal needs no custom calibration, removes near-end and far-end crosstalk of differential fixtures and supports fixtures with one end open.

YNA-720 Series applications

  • Semiconductor and chip testing

    Automatic fixture removal extracts and de-embeds fixture parameters for packaged and in-chip microwave devices that cannot connect directly to the analyzer.

  • Material measurements

  • Radar T/R components and antenna transceiver modules

    Swept pulse S-parameter, pulse envelope and pulse point tests run with internal or external pulse synchronization.

  • High-speed cables and interconnects

    One view combines time-domain and frequency-domain analysis to locate impedance discontinuities, reflections and near-end or far-end crosstalk, and simulated eye diagrams run pass/fail templates.

  • Microwave components and filters

    Limit, ripple and filter bandwidth tests run on the analyzer, with display formats from log magnitude and group delay to Smith chart.

  • Mixers, converters and differential active devices

    Scalar conversion loss, vector amplitude, absolute phase and absolute delay cover mixers and converters; differential I/Q and THD functions cover differential amplifiers and I/Q mixers.

Semiconductor and chip testing

Material measurements

Antennas and radar T/R modules

More figures (3)

High-speed cables and interconnects

Microwave components and filters

Mixers, converters and active devices

Application images show typical use settings; they do not indicate measured performance.

YNA-720 Series specifications

Full specification table — 23 published parameters

Parameter Specification
Frequency characteristic
Frequency range 10 MHz to 26.5 GHz / 10 MHz to 44 GHz / 10 MHz to 67 GHz By model
Frequency resolution 0.1 Hz
Frequency accuracy ±1 × 10^-7 23 °C ±3 °C
Main features
Measurement points 200,001 Stated for the series
Dynamic range
Dynamic range Up to 140 dB Stated for the series
Pulse characteristic
Pulse width setting range 33 ns to 70 s; Typical: 20 ns to 70 s
Pulse S-parameter measurement
Pulse period Up to 70 s Pulse S-parameter measurement; Stated for the series
Pulse resolution As low as 8.3 ns Pulse S-parameter measurement; Stated for the series
Broadband synchronous pulse width < 42 ns Pulse S-parameter measurement; Stated for the series
Others
IF bandwidth 1 Hz to 30 MHz
Amplitude display resolution 0.001 dB/div
Phase display resolution 0.001°/div
Show all 23 specifications Reference input/output, Measured ports, Peripheral interfaces
Parameter Specification
Peripheral interfaces
Reference input/output 10 MHz
General characteristic
Measured ports 2 ports standard
Peripheral interfaces GPIB, USB, DP and LAN
Display 15.6-inch high-resolution touch display
Dimensions (W × H × D) 2-port: 475 mm × 279 mm × 560 mm; 4-port: 475 mm × 279 mm × 660 mm Including handles, feet and pads
Maximum power consumption 500 W
Power supply 50 Hz 220 V or 50 Hz/60 Hz 110 V AC
Maximum weight 50 kg
Port connectors 3.5 mm (male), 50 Ω system impedance Models: YNA-720-26G5
Port connectors 2.4 mm, 50 Ω system impedance Models: YNA-720-44G
Port connectors 1.85 mm, 50 Ω system impedance Models: YNA-720-67G
Detailed specification tables (14) 236 rows
Specification configurations
ConfigurationDefinition
Standard / four-portMax. output power: standard configuration or four-port measurement configuration. System dynamic range: standard or four-port measurement configuration.
Measurement optionsFour-port measurement, four-port programmable step attenuator, active intermodulation distortion measurement, configurable test set, and noise figure measurement options.

Models: YNA-720-26G5, YNA-720-44G, YNA-720-67G

Definitions for the Standard / four-port and Measurement options entries in the output-power and system-dynamic-range tables of all three models.

YNA-720-26G5: Harmonic suppression (6 rows) Models: YNA-720-26G5
YNA-720-26G5: Harmonic suppression
Frequency rangeSpecificationTypical
Ports 1 and 3
0.01-4 GHz-48 dBc-62 dBc
4-14 GHz-57 dBc-68 dBc
14-26.5 GHz-57 dBc-70 dBc
Ports 2 and 4
0.01-4 GHz-13 dBc-24 dBc
4-14 GHz-18 dBc-30 dBc
14-26.5 GHz-18 dBc-36 dBc

Models: YNA-720-26G5

YNA-720-26G5: Port power characteristics (14 rows) Models: YNA-720-26G5
YNA-720-26G5: Port power characteristics
Frequency rangeSpecificationTypical
Power sweep range
10-50 MHz33 dB36 dB
0.05-4 GHz35 dB39 dB
4-16 GHz38 dB41 dB
16-20 GHz35 dB40 dB
20-24 GHz32 dB39 dB
24-26.5 GHz27 dB38 dB
Max. output power / Standard / four-port
10-50 MHz+13 dBm+16 dBm
0.05-14 GHz+13 dBm+15 dBm
14-20 GHz+13 dBm+15 dBm
24-26.5 GHz+10 dBm+14 dBm
Max. output power / Measurement options
10-50 MHz+10 dBm+12 dBm
0.05-14 GHz+7 dBm+10 dBm
14-20 GHz+5 dBm+10 dBm
24-26.5 GHz+3 dBm+7 dBm

Models: YNA-720-26G5

YNA-720-26G5: Network parameter characteristics (25 rows) Models: YNA-720-26G5
YNA-720-26G5: Network parameter characteristics
Frequency rangeSpecificationTypical
System dynamic range / Standard / four-port
10-50 MHz96 dB108 dB
50-500 MHz110 dB124 dB
0.5-4 GHz130 dB140 dB
4-14 GHz133 dB140 dB
14-20 GHz131 dB133 dB
20-26.5 GHz125 dB128 dB
System dynamic range / Measurement options
10-50 MHz96 dB105 dB
50-500 MHz110 dB120 dB
0.5-4 GHz120 dB134 dB
4-14 GHz120 dB134 dB
14-20 GHz115 dB128 dB
20-26.5 GHz115 dB122 dB
Effective directivity
0.01-2 GHz48 dB65 dB
2-26.5 GHz44 dB52 dB
Effective source match
0.01-2 GHz40 dB46 dB
2-26.5 GHz31 dB36 dB
Effective load match
0.01-2 GHz47 dB61 dB
2-26.5 GHz44 dB56 dB
Reflection tracking
0.01-2 GHz±0.0150 dB±0.0060 dB
2-26.5 GHz±0.0161 dB±0.0030 dB
Transmission tracking
10-50 MHz±0.044 dB±0.001 dB
0.05-2 GHz±0.055 dB±0.002 dB
2-9 GHz±0.120 dB±0.004 dB
9-14 GHz±0.110 dB±0.005 dB
14-26.5 GHz±0.120 dB±0.008 dB

Models: YNA-720-26G5

YNA-720-26G5: Trace noise (14 rows) Models: YNA-720-26G5
YNA-720-26G5: Trace noise
Frequency rangeSpecificationTypical
Amplitude trace noise (dB rms)
10-100 MHz0.00700.0040
100-500 MHz0.00200.0017
0.5-1 GHz0.00200.0006
1-14 GHz0.00200.0006
14-22.5 GHz0.00200.0007
22.5-24 GHz0.00300.0008
24-26.5 GHz0.00500.0007
Phase trace noise (° rms)
10-100 MHz0.0510.030
100-500 MHz0.0150.012
0.5-1 GHz0.0150.004
1-14 GHz0.0150.004
14-22.5 GHz0.0420.005
22.5-24 GHz0.0540.005
24-26.5 GHz0.0540.005

Models: YNA-720-26G5

IF bandwidth: 1 kHz.

YNA-720-44G: Harmonic suppression (6 rows) Models: YNA-720-44G
YNA-720-44G: Harmonic suppression
Frequency rangeSpecificationTypical
Ports 1 and 3
0.01-4 GHz-48 dBc-68 dBc
4-14 GHz-57 dBc-70 dBc
14-44 GHz-57 dBc-70 dBc
Ports 2 and 4
0.01-4 GHz-13 dBc-18 dBc
4-14 GHz-18 dBc-31 dBc
14-44 GHz-57 dBc-70 dBc

Models: YNA-720-44G

YNA-720-44G: Port power characteristics (22 rows) Models: YNA-720-44G
YNA-720-44G: Port power characteristics
Frequency rangeSpecificationTypical
Power sweep range
10-50 MHz37 dB42 dB
0.05-2 GHz38 dB44 dB
2-4 GHz35 dB41 dB
4-26.5 GHz38 dB41 dB
26.5-30 GHz37 dB42 dB
30-32 GHz36 dB40 dB
32-35 GHz37 dB43 dB
35-44 GHz34 dB39 dB
Max. output power / Standard / four-port
10-50 MHz+12 dBm+14 dBm
0.05-4 GHz+12 dBm+13 dBm
4-14 GHz+12 dBm+14 dBm
14-20 GHz+13 dBm+14 dBm
20-26.5 GHz+13 dBm+14 dBm
26.5-40 GHz+12 dBm+15 dBm
40-44 GHz+9 dBm+13 dBm
Max. output power / Measurement options
10-50 MHz+9 dBm+10 dBm
0.05-4 GHz+4 dBm+7 dBm
4-14 GHz+4 dBm+7 dBm
14-20 GHz+8 dBm+9 dBm
20-26.5 GHz+6 dBm+9 dBm
26.5-40 GHz+4 dBm+7 dBm
40-44 GHz-1 dBm+1 dBm

Models: YNA-720-44G

YNA-720-44G: Network parameter characteristics (35 rows) Models: YNA-720-44G
YNA-720-44G: Network parameter characteristics
Frequency rangeSpecificationTypical
System dynamic range / Standard / four-port
10-50 MHz89 dB104 dB
50-500 MHz106 dB122 dB
0.5-4 GHz130 dB137 dB
4-14 GHz130 dB139 dB
14-20 GHz128 dB138 dB
20-26.5 GHz130 dB138 dB
26.5-40 GHz125 dB133 dB
40-44 GHz122 dB130 dB
System dynamic range / Measurement options
10-50 MHz83 dB97 dB
50-500 MHz100 dB108 dB
0.5-4 GHz114 dB125 dB
4-14 GHz112 dB132 dB
14-20 GHz116 dB128 dB
20-26.5 GHz114 dB127 dB
26.5-40 GHz112 dB125 dB
40-44 GHz106 dB119 dB
Effective directivity
0.01-2 GHz41 dB59 dB
2-20 GHz38 dB54 dB
20-44 GHz36 dB47 dB
Effective source match
0.01-2 GHz31 dB45 dB
2-20 GHz30 dB36 dB
20-44 GHz23 dB31 dB
Effective load match
0.01-2 GHz42 dB58 dB
2-20 GHz37 dB55 dB
20-44 GHz35 dB51 dB
Reflection tracking
0.01-2 GHz±0.0150 dB±0.0046 dB
2-20 GHz±0.0290 dB±0.0022 dB
20-40 GHz±0.0300 dB±0.0020 dB
40-44 GHz±0.0400 dB±0.0065 dB
Transmission tracking
10-50 MHz±0.051 dB±0.002 dB
0.05-2 GHz±0.030 dB±0.004 dB
2-10 GHz±0.095 dB±0.002 dB
10-20 GHz±0.120 dB±0.002 dB
20-40 GHz±0.200 dB±0.005 dB
40-44 GHz±0.200 dB±0.002 dB

Models: YNA-720-44G

YNA-720-44G: Trace noise (10 rows) Models: YNA-720-44G
YNA-720-44G: Trace noise
Frequency rangeSpecificationTypical
Amplitude trace noise (dB rms)
10-50 MHz0.20000.0039
50-500 MHz0.02000.0006
0.5-1 GHz0.00300.0005
1-26.5 GHz0.00200.0006
26.5-44 GHz0.00300.0007
Phase trace noise (° rms)
10-50 MHz1.0000.024
50-500 MHz0.5000.004
0.5-1 GHz0.0200.003
1-26.5 GHz0.0200.004
26.5-44 GHz0.0300.005

Models: YNA-720-44G

IF bandwidth: 1 kHz.

YNA-720-67G: Harmonic suppression (6 rows) Models: YNA-720-67G
YNA-720-67G: Harmonic suppression
Frequency rangeSpecificationTypical
Ports 1 and 3
0.01-4 GHz-48 dBc-57 dBc
4-14 GHz-57 dBc-70 dBc
14-67 GHz-57 dBc-71 dBc
Ports 2 and 4
0.01-4 GHz-13 dBc-25 dBc
4-14 GHz-18 dBc-32 dBc
14-67 GHz-57 dBc-72 dBc

Models: YNA-720-67G

YNA-720-67G: Port power characteristics (31 rows) Models: YNA-720-67G
YNA-720-67G: Port power characteristics
Frequency rangeSpecificationTypical
Power sweep range
10-50 MHz35 dB41 dB
0.05-2 GHz38 dB44 dB
2-4 GHz35 dB40 dB
4-10 GHz38 dB42 dB
10-14 GHz36 dB43 dB
14-16 GHz37 dB42 dB
16-19 GHz35 dB40 dB
19-26.5 GHz34 dB37 dB
26.5-30 GHz33 dB37 dB
30-32 GHz32 dB36 dB
32-35 GHz32 dB39 dB
35-40 GHz30 dB36 dB
40-67 GHz35 dB40 dB
Max. output power / Standard / four-port
10-50 MHz+10 dBm+16 dBm
0.05-14 GHz+10 dBm+14 dBm
14-20 GHz+12 dBm+16 dBm
20-26.5 GHz+11 dBm+14 dBm
26.5-30 GHz+10 dBm+13 dBm
30-32 GHz+7 dBm+10 dBm
32-35 GHz+9 dBm+12 dBm
35-40 GHz+5 dBm+11 dBm
40-67 GHz+10 dBm+16 dBm
Max. output power / Measurement options
10-50 MHz+6 dBm+10 dBm
0.05-14 GHz+4 dBm+9 dBm
14-20 GHz+4 dBm+11 dBm
20-26.5 GHz+4 dBm+7 dBm
26.5-30 GHz-2 dBm+6 dBm
30-32 GHz-2 dBm+4 dBm
32-35 GHz-2 dBm+5 dBm
35-40 GHz-2 dBm+3 dBm
40-67 GHz-2 dBm+4 dBm

Models: YNA-720-67G

YNA-720-67G: Network parameter characteristics (48 rows) Models: YNA-720-67G
YNA-720-67G: Network parameter characteristics
Frequency rangeSpecificationTypical
System dynamic range / Standard / four-port
10-50 MHz87 dB102 dB
50-500 MHz110 dB124 dB
0.5-4 GHz127 dB137 dB
4-14 GHz130 dB142 dB
14-26.5 GHz129 dB138 dB
26.5-40 GHz120 dB134 dB
40-50 GHz116 dB128 dB
50-60 GHz107 dB118 dB
60-67 GHz106 dB116 dB
System dynamic range / Measurement options
10-50 MHz84 dB100 dB
50-500 MHz101 dB120 dB
0.5-4 GHz114 dB129 dB
4-14 GHz113 dB130 dB
14-26.5 GHz113 dB128 dB
26.5-40 GHz105 dB118 dB
40-50 GHz106 dB115 dB
50-60 GHz101 dB112 dB
60-67 GHz100 dB106 dB
Effective directivity
0.01-2 GHz35 dB65 dB
2-10 GHz41 dB65 dB
10-20 GHz38 dB59 dB
20-35 GHz37 dB54 dB
35-50 GHz37 dB48 dB
50-67 GHz34 dB40 dB
Effective source match
0.01-2 GHz34 dB43 dB
2-10 GHz36 dB40 dB
10-20 GHz40 dB42 dB
20-35 GHz34 dB38 dB
35-50 GHz28 dB31 dB
50-67 GHz28 dB31 dB
Effective load match
0.01-2 GHz34 dB59 dB
2-10 GHz40 dB66 dB
10-20 GHz36 dB66 dB
20-35 GHz35 dB57 dB
35-50 GHz36 dB59 dB
50-67 GHz33 dB55 dB
Reflection tracking
0.01-2 GHz±0.0200 dB±0.0050 dB
2-10 GHz±0.0110 dB±0.0016 dB
10-35 GHz±0.0330 dB±0.0037 dB
35-50 GHz±0.0200 dB±0.0045 dB
50-67 GHz±0.0310 dB±0.0180 dB
Transmission tracking
0.01-2 GHz±0.100 dB±0.002 dB
2-10 GHz±0.065 dB±0.002 dB
10-20 GHz±0.100 dB±0.002 dB
20-35 GHz±0.110 dB±0.003 dB
35-50 GHz±0.094 dB±0.004 dB
50-60 GHz±0.140 dB±0.006 dB
60-67 GHz±0.150 dB±0.009 dB

Models: YNA-720-67G

YNA-720-67G: Trace noise (11 rows) Models: YNA-720-67G
YNA-720-67G: Trace noise
Frequency rangeSpecificationTypical
Amplitude trace noise (dB rms)
10-50 MHz0.05000.0042
50-100 MHz0.00400.0030
100-500 MHz0.00200.0006
0.5-1 GHz0.00300.0004
1-26.5 GHz0.00200.0003
26.5-50 GHz0.00300.0009
50-67 GHz0.03000.0077
Phase trace noise (° rms)
10-50 MHz0.4000.029
0.05-26.5 GHz0.0200.008
26.5-50 GHz0.0300.008
50-67 GHz0.2000.051

Models: YNA-720-67G

IF bandwidth: 1 kHz.

Pulse on/off ratio (6 rows) Models: YNA-720-26G5, YNA-720-44G, YNA-720-67G
Pulse on/off ratio
ModelFrequency rangeOn/off ratio
YNA-720-26G50.01-4 GHz64 dB
YNA-720-26G54-26.5 GHz80 dB
YNA-720-44G0.01-4 GHz64 dB
YNA-720-44G4-44 GHz80 dB
YNA-720-67G0.01-4 GHz64 dB
YNA-720-67G4-67 GHz80 dB

Models: YNA-720-26G5, YNA-720-44G, YNA-720-67G

Product and technical media

Pulse S-parameter measurement

Gain compression measurement

Spectrum analysis measurement

Fixture de-embedding diagram

More figures (2)

Eye-diagram analysis

Scalar conversion-loss results

YNA-720 Series models, configuration and compatibility

Model Frequency range Port connectors Measured ports
YNA-720-26G5 10 MHz to 26.5 GHz3.5 mm (male), 50 ΩStandard: 2 ports YNA-720-26G5-400 option: 4 ports
YNA-720-44G 10 MHz to 44 GHz2.4 mm, 50 ΩStandard: 2 ports YNA-720-44G-400 option: 4 ports
YNA-720-67G 10 MHz to 67 GHz1.85 mm, 50 ΩStandard: 2 ports YNA-720-67G-400 option: 4 ports

Options

CodeDescriptionModelsStandardRequires / excludes
YNA-720-26G5-400 / YNA-720-44G-400 / YNA-720-67G-400Four-port measurement. 4 measured ports in place of the standard 2 portsYNA-720-26G5 to YNA-720-67GOptional—
YNA-720-26G5-003 / YNA-720-44G-003 / YNA-720-67G-003Noise figure measurement. For accurate measurement of S parameters, noise coefficient, and noise parametersYNA-720-26G5 to YNA-720-67GNot statedYNA-720-26G5-003: 2-Port Requires: Option YNA-720-26G5-201 + YNA-720-26G5-204; 4-Port Requires: Option YNA-720-26G5-401 + YNA-720-26G5-404. YNA-720-44G-003: 2-Port Requires: Option YNA-720-44G-201 + YNA-720-44G-204; 4-Port Requires: Option YNA-720-44G-401 + YNA-720-44G-404. YNA-720-67G-003: 2-Port Requires: Option YNA-720-67G-201 + YNA-720-67G-204; 4-Port Requires: Option YNA-720-67G-401 + YNA-720-67G-404. Two-port electronic calibrators and ordinary noise sources need to be purchased separately.

Accessories

CodeDescriptionModelsNote
GPM40-UUSB CW power sensor, 50 MHz to 40 GHz, -70 dBm to +20 dBm.Not statedUSB CW Power Sensor
XNF40-UUSB noise source, 10 MHz to 40 GHz, ENR 12 dB to 19 dB.Not statedUSB Noise Source

Choose the YNA-720 Series model by the highest frequency of the device under test, which also sets the port connector size. The per-model tables give maximum output power and system dynamic range twice: for the standard configuration, and for a configuration with measurement options such as the programmable step attenuator and configurable test set, where the printed output power and dynamic range are lower.

YNA-720 Series selection guidance

Format
Benchtop vector network analyzer, 2 ports standard
Coverage
Frequency range 10 MHz to 26.5 GHz / 10 MHz to 44 GHz / 10 MHz to 67 GHz by model; IF bandwidth 1 Hz to 30 MHz
Best for
Semiconductor, material, antenna, high-speed cable and microwave component tests that combine several measurement functions through one connection.
Compare products in the Network Analyzers category

YNA-720 Series technical resources

Download Datasheet

PDF technical specifications

Request a quote for the YNA-720 Series

Share the application, required configuration and documentation needs for the YNA-720 Series, or compare it with other products in the Network Analyzers category first. XGY Tek reviews each request and confirms model, options and delivery documentation in the quotation.

Before requesting a quote

What to include in a quote request (5)

For a YNA-720 Series quotation, state the points below so the right model and option set can be checked.

  • The highest DUT frequency, which selects the YNA-720-26G5, YNA-720-44G or YNA-720-67G and with it the port connector size.
  • Whether you need four-port measurement (option -400, listed for YNA-720-26G5 to YNA-720-67G), which adds 2 ports and makes the unit deeper.
  • The measurement functions you need, such as pulse, mixer and converter, gain compression, spectrum, signal integrity or differential I/Q, because available functions depend on the configured hardware and measurement options.
  • The calibration kit or electronic calibration module you will use, because the datasheet lists no standard delivery contents or calibration standards.
  • Any USB accessories by part number, such as the GPM40-U power sensor or XNF40-U noise source, and the connector gender you need on the YNA-720-44G or YNA-720-67G.