Power Supplies
XPAL-3000 High Precision Programmable AC Load
High Precision Programmable AC Load; Load function — Rated current: 27A@105 ~ 135V 13.6A@215 ~ 240V
XGY XPAL-3000 is a high precision programmable AC load, a program-controlled adjustable load box, which can also be manually controlled. Test by setting different power, current and resistance under fixed voltage.
- Type
- AC load
- Power
- 3000 W Rated load power
- Voltage
- 80 to 240 V AC Load input; rated 110 V / 220 V
- Current
- 27 A / 13.6 A At 105 to 135 V / 215 to 240 V
XPAL-3000 overview
XGY XPAL-3000 is a high precision programmable AC load with a rated load power of 3000 W: a program-controlled adjustable load box, which can also be manually controlled, for testing AC sources at a fixed voltage by setting power, current or resistance.
The XPAL-3000 load function has a rated current of 27 A at 105 to 135 V and 13.6 A at 215 to 240 V, so one unit covers sources in both the lower and the upper voltage band at power factor 1.0. The XPAL-3000 has half the rated power and rated current of the XPAL-6000 and a lower, shallower chassis.
XPAL-3000: Intelligent operation achieves the function of constant power or constant current or resistance. 24-bit AD conversion is adopted, the sampling period is about 8000 times/s, and the voltage and current are sampled simultaneously. New power consumption components are adopted with high power density, and forced air cooling is adopted for heat dissipation.
The XPAL-3000 connects to a PC or controller over RS-232 with Modbus RTU, so the load can be program-controlled from a test script.
Rear panel
RS-232 Debug L N AC220V.
Setup and Measurement Screen
Note: Auto Compensation/No Compensation Press and hold for 3 seconds to switch.
Auto compensation, adjust the load according to the actual voltage to achieve constant power/constant current function.
No compensation, test at preset voltage and load.
Virtual numeric keypad entry, allowing 2 decimal places.
Communication interface RS-232
Use an RS-232 cable with a DB-9 interface (male to female direct connection) to connect to the serial port of the controller (such as a PC).
Product maintenance
Clean the chassis and panel regularly to prevent dust accumulation at the input and output ports.
Do not place heavy sundries and liquid containers on the chassis.
Avoid working in places with volatile flammable liquids and conductive fiber dust.
Key figures
- Rated current
- 27A@105 ~ 135V 13.6A@215 ~ 240V
- Load function
- Power setting accuracy
- 20W
- Load function
- Product name
- High Precision Programmable AC Load
- RS-232
- Baud rate 9600
XPAL-3000 capabilities and applications
XPAL-3000 applications
-
Battery pack power detection
-
Inverter power detection
-
Intelligent switch power detection
XPAL-3000 specifications
Full specification table — 25 published parameters
| Parameter | Specification |
|---|---|
| Technical indicators | |
| Product name | High Precision Programmable AC Load |
| Working power | |
| Input voltage | AC220V±10% 50Hz |
| Rated power | 60W |
| Communication | |
| RS-232 | Baud rate 9600 |
| Load function | |
| Input voltage | AC80 ~ 240V; Rated AC110V/AC220V Load function |
| Enter the frequency | 50Hz/60Hz Load function |
| Rated power | 3000W Load function |
| Rated current | 27A@105 ~ 135V 13.6A@215 ~ 240V Load function |
| Power setting accuracy | 20W Load function |
| Current setting accuracy | 0.09A Load function |
| Load return actual accuracy | -3% + 1.5% or ± 20W |
| Resistance setting range and accuracy | 4.1 ~ 600Ω@110V 7 ~ 2400Ω@220V ±5% Load function |
Show all 25 specifications
| Parameter | Specification |
|---|---|
| Load function | |
| Power factor | PF=1.0 Load function |
| Heat dissipation mode | Air Cooling Load function |
| Other functions | Unload/short circuit Load function |
| Measurement and error | |
| Voltage | ± (0.1% of reading + 0.2% of span) Measurement and error |
| Electric current | ± (0.1% of reading + 0.1% of span) Measurement and error |
| Active power | ± (0.1% of reading + 0.1% of span) Measurement and error |
| Frequency | ±0.1% Measurement and error |
| Power factor | ±0.02 Measurement and error |
| Work environment | |
| Temperature | 0 ~ 40°C |
| Humidity | ≤85%RH |
| Atmospheric pressure | 86 ~ 106kPa (4000m and below) |
| Size L* H*D | 481.8mm x 180mm x 568mm |
| Weight net weight | About 17 Kg |
Detailed specification tables (3)
| Model | XPAL-3000 |
|---|---|
| Overvoltage | — |
| Overpower | — |
| Overtemperature | — |
| Pin No. | Description |
|---|---|
| 1 | No connection |
| 2 | TXD, transmit data |
| 3 | RXD, receive data |
| 4 | No connection |
| 5 | GND |
| 6 | No connection |
| 7 | No connection |
| 8 | No connection |
| 9 | No connection |
| Agreement | Baud rate | Digit | Stop Bit | Check |
|---|---|---|---|---|
| Modbus_RTU | 9600 | 8 | 1 | N |
Product and technical media
Dimensional drawing (unit: mm)
Communication interface RS-232
XPAL-3000 models, configuration and compatibility
XPAL-3000 selection guidance
- Format
- High Precision Programmable AC Load
- Coverage
- Load function — Rated current: 27A@105 ~ 135V 13.6A@215 ~ 240V
- Best for
- Power detection of battery pack, inverter, intelligent switch and other products.
XPAL-3000 technical resources
Request a quote for the XPAL-3000
Share the application, required configuration and documentation needs for the XPAL-3000, or compare it with other products in the Power Supplies category first. XGY Tek reviews each request and confirms model, options and delivery documentation in the quotation.
Before requesting a quote
An XPAL-3000 quotation request should state the following points, which decide between the XPAL-3000 and the XPAL-6000 and the system set-up.
- The source voltage under test and its maximum current, since the XPAL-3000 rated current differs between the lower and the upper voltage band.
- Which XPAL-3000 functions the test sequence relies on, so the set-up can be confirmed before delivery.
- Whether a PC or PLC will run the load over Modbus RTU, since RS-232 is the only communication port printed.