Power Supplies
XPAL-6000 High Precision Programmable AC Load
High Precision Programmable AC Load; Load function — Rated current: 54A@105 ~ 135V 27A@215 ~ 240V
XGY XPAL-6000 is a high precision programmable AC load, a program-controlled adjustable load box, which can also be manually controlled. Test by setting different power, current and resistance under fixed voltage.
- Type
- AC load
- Power
- 6000 W Rated load power
- Voltage
- 80 to 240 V AC Load input; rated 110 V / 220 V
- Current
- 54 A / 27 A At 105 to 135 V / 215 to 240 V
XPAL-6000 overview
XGY XPAL-6000 is the higher-power high precision programmable AC load of the XPAL pair, with a rated load power of 6000 W for testing larger AC sources. Run from a program or by hand, the XPAL-6000 loads an AC source at a fixed voltage with a set power, current or resistance.
The XPAL-6000 load function has a rated current of 54 A at 105 to 135 V and 27 A at 215 to 240 V, double the XPAL-3000 figures, so it is the model to choose when an inverter or battery-pack output exceeds the XPAL-3000 rating.
In operation the XPAL-6000 holds constant power, constant current or a set resistance. The XPAL-6000 samples voltage and current at the same instant with 24-bit A/D conversion at about 8000 times/s, and its high-power-density load components are cooled by forced air.
The XPAL-6000 takes commands from a PC or controller over RS-232 using Modbus RTU, and its chassis is taller and deeper than that of the XPAL-3000.
Setup and Measurement Screen
Note: Auto Compensation/No Compensation Press and hold for 3 seconds to switch.
Auto compensation, adjust the load according to the actual voltage to achieve constant power/constant current function.
No compensation, test at preset voltage and load.
Virtual numeric keypad entry, allowing 2 decimal places.
Communication interface RS-232
Use an RS-232 cable with a DB-9 interface (male to female direct connection) to connect to the serial port of the controller (such as a PC).
Product maintenance
Clean the chassis and panel regularly to prevent dust accumulation at the input and output ports.
Do not place heavy sundries and liquid containers on the chassis.
Avoid working in places with volatile flammable liquids and conductive fiber dust.
Key figures
- Rated current
- 54A@105 ~ 135V 27A@215 ~ 240V
- Load function
- Power setting accuracy
- 20W
- Load function
- Product name
- High Precision Programmable AC Load
- RS-232
- Baud rate 9600
XPAL-6000 capabilities and applications
XPAL-6000 applications
-
Power detection on battery packs
-
Power detection on inverters
-
Power detection on intelligent switches
XPAL-6000 specifications
Full specification table — 25 published parameters
| Parameter | Specification |
|---|---|
| Technical indicators | |
| Product name | High Precision Programmable AC Load |
| Working power | |
| Input voltage | AC220V±10% 50Hz |
| Rated power | 100W |
| Communication | |
| RS-232 | Baud rate 9600 |
| Load function | |
| Input voltage | AC80 ~ 240V; Rated AC110V/AC220V Load function |
| Enter the frequency | 50Hz/60Hz Load function |
| Rated power | 6000W Load function |
| Rated current | 54A@105 ~ 135V 27A@215 ~ 240V Load function |
| Power setting accuracy | 20W Load function |
| Current setting accuracy | 0.09A Load function |
| Load return actual accuracy | -3% + 1.5% or ± 20W |
| Resistance setting range and accuracy | 4.1 ~ 600Ω@110V 14 ~ 2400Ω@220V ±5% Load function |
Show all 25 specifications
| Parameter | Specification |
|---|---|
| Load function | |
| Power factor | PF=1.0 Load function |
| Heat dissipation mode | Air Cooling Load function |
| Other functions | Unload/short circuit Load function |
| Measurement and error | |
| Voltage | ± (0.1% of reading + 0.2% of span) Measurement and error |
| Electric current | ± (0.1% of reading + 0.1% of span) Measurement and error |
| Active power | ± (0.1% of reading + 0.1% of span) Measurement and error |
| Frequency | ±0.1% Measurement and error |
| Power factor | ±0.02 Measurement and error |
| Work environment | |
| Temperature | 0 ~ 40°C |
| Humidity | ≤85%RH |
| Atmospheric pressure | 86 ~ 106kPa (4000m and below) |
| Size L* H*D | 483mm x 264mm x 632mm |
| Weight net weight | About 17 Kg |
Detailed specification tables (3)
| Model | XPAL-6000 |
|---|---|
| Overvoltage | — |
| Overpower | — |
| Overtemperature | — |
| Pin No. | Description |
|---|---|
| 1 | No connection |
| 2 | TXD, transmit data |
| 3 | RXD, receive data |
| 4 | No connection |
| 5 | GND |
| 6 | No connection |
| 7 | No connection |
| 8 | No connection |
| 9 | No connection |
| Agreement | Baud rate | Digit | Stop Bit | Check |
|---|---|---|---|---|
| Modbus_RTU | 9600 | 8 | 1 | N |
Product and technical media
Communication interface RS-232
XPAL-6000 models, configuration and compatibility
XPAL-6000 selection guidance
- Format
- High Precision Programmable AC Load
- Coverage
- Load function — Rated current: 54A@105 ~ 135V 27A@215 ~ 240V
- Best for
- Power detection of battery pack, inverter, intelligent switch and other products.
XPAL-6000 technical resources
Request a quote for the XPAL-6000
Share the application, required configuration and documentation needs for the XPAL-6000, or compare it with other products in the Power Supplies category first. XGY Tek reviews each request and confirms model, options and delivery documentation in the quotation.
Before requesting a quote
An XPAL-6000 quotation request should state the following points, which confirm the model and the station set-up.
- The highest source current in each voltage band, to confirm that the XPAL-6000 rather than the XPAL-3000 is needed.
- The bench or rack position, since the XPAL-6000 chassis is taller and deeper than the XPAL-3000.
- The control software or PLC that will drive the Modbus RTU link.