Skip to content

Power Supplies

XPAL-6000 High Precision Programmable AC Load

High Precision Programmable AC Load; Load function — Rated current: 54A@105 ~ 135V 27A@215 ~ 240V

XGY XPAL-6000 is a high precision programmable AC load, a program-controlled adjustable load box, which can also be manually controlled. Test by setting different power, current and resistance under fixed voltage.

XPAL-6000 High Precision Programmable AC Load
Type
AC load
Power
6000 W Rated load power
Voltage
80 to 240 V AC Load input; rated 110 V / 220 V
Current
54 A / 27 A At 105 to 135 V / 215 to 240 V

XPAL-6000 overview

XGY XPAL-6000 is the higher-power high precision programmable AC load of the XPAL pair, with a rated load power of 6000 W for testing larger AC sources. Run from a program or by hand, the XPAL-6000 loads an AC source at a fixed voltage with a set power, current or resistance.

The XPAL-6000 load function has a rated current of 54 A at 105 to 135 V and 27 A at 215 to 240 V, double the XPAL-3000 figures, so it is the model to choose when an inverter or battery-pack output exceeds the XPAL-3000 rating.

In operation the XPAL-6000 holds constant power, constant current or a set resistance. The XPAL-6000 samples voltage and current at the same instant with 24-bit A/D conversion at about 8000 times/s, and its high-power-density load components are cooled by forced air.

The XPAL-6000 takes commands from a PC or controller over RS-232 using Modbus RTU, and its chassis is taller and deeper than that of the XPAL-3000.

Setup and Measurement Screen

Note: Auto Compensation/No Compensation Press and hold for 3 seconds to switch.

Auto compensation, adjust the load according to the actual voltage to achieve constant power/constant current function.

No compensation, test at preset voltage and load.

Virtual numeric keypad entry, allowing 2 decimal places.

Communication interface RS-232

Use an RS-232 cable with a DB-9 interface (male to female direct connection) to connect to the serial port of the controller (such as a PC).

Product maintenance

Clean the chassis and panel regularly to prevent dust accumulation at the input and output ports.

Do not place heavy sundries and liquid containers on the chassis.

Avoid working in places with volatile flammable liquids and conductive fiber dust.

Key figures

Rated current
54A@105 ~ 135V 27A@215 ~ 240V
Load function
Power setting accuracy
20W
Load function
Product name
High Precision Programmable AC Load
RS-232
Baud rate 9600

XPAL-6000 capabilities and applications

XPAL-6000 applications

  • Power detection on battery packs

  • Power detection on inverters

  • Power detection on intelligent switches

XPAL-6000 specifications

Full specification table — 25 published parameters

Parameter Specification
Technical indicators
Product name High Precision Programmable AC Load
Working power
Input voltage AC220V±10% 50Hz
Rated power 100W
Communication
RS-232 Baud rate 9600
Load function
Input voltage AC80 ~ 240V; Rated AC110V/AC220V Load function
Enter the frequency 50Hz/60Hz Load function
Rated power 6000W Load function
Rated current 54A@105 ~ 135V 27A@215 ~ 240V Load function
Power setting accuracy 20W Load function
Current setting accuracy 0.09A Load function
Load return actual accuracy -3% + 1.5% or ± 20W
Resistance setting range and accuracy 4.1 ~ 600Ω@110V 14 ~ 2400Ω@220V ±5% Load function
Show all 25 specifications Power factor, Heat dissipation mode, Other functions
Parameter Specification
Load function
Power factor PF=1.0 Load function
Heat dissipation mode Air Cooling Load function
Other functions Unload/short circuit Load function
Measurement and error
Voltage ± (0.1% of reading + 0.2% of span) Measurement and error
Electric current ± (0.1% of reading + 0.1% of span) Measurement and error
Active power ± (0.1% of reading + 0.1% of span) Measurement and error
Frequency ±0.1% Measurement and error
Power factor ±0.02 Measurement and error
Work environment
Temperature 0 ~ 40°C
Humidity ≤85%RH
Atmospheric pressure 86 ~ 106kPa (4000m and below)
Size L* H*D 483mm x 264mm x 632mm
Weight net weight About 17 Kg
Detailed specification tables (3) 13 rows
Protection function
ModelXPAL-6000
Overvoltage—
Overpower—
Overtemperature—
RS-232 interface description
Pin No.Description
1No connection
2TXD, transmit data
3RXD, receive data
4No connection
5GND
6No connection
7No connection
8No connection
9No connection
Communication parameters
AgreementBaud rateDigitStop BitCheck
Modbus_RTU960081N

Product and technical media

Communication interface RS-232

XPAL-6000 models, configuration and compatibility

XPAL-6000 selection guidance

Format
High Precision Programmable AC Load
Coverage
Load function — Rated current: 54A@105 ~ 135V 27A@215 ~ 240V
Best for
Power detection of battery pack, inverter, intelligent switch and other products.
Compare products in the Power Supplies category

XPAL-6000 technical resources

Download Datasheet

PDF technical specifications

Request a quote for the XPAL-6000

Share the application, required configuration and documentation needs for the XPAL-6000, or compare it with other products in the Power Supplies category first. XGY Tek reviews each request and confirms model, options and delivery documentation in the quotation.

Before requesting a quote

An XPAL-6000 quotation request should state the following points, which confirm the model and the station set-up.

  • The highest source current in each voltage band, to confirm that the XPAL-6000 rather than the XPAL-3000 is needed.
  • The bench or rack position, since the XPAL-6000 chassis is taller and deeper than the XPAL-3000.
  • The control software or PLC that will drive the Modbus RTU link.