Power Supplies
XDC100SA Series Programmable DC Power Supply
36 W to 360 W Programmable DC Supply by Model
XDC100SA is a single-channel programmable DC supply family with 12 models spanning 36 to 360 W. Selected models reach 150 V or 10 A, with list sequencing, four-wire remote sense and DVM measurements.
Get a Quote
- Power range
- 36 to 360 W
- Voltage
- Up to 150 V (model dependent)
- Current
- Up to 10 A (model dependent)
- Display resolution
- 0.1 mV / 1 µA
- Stated for the series
Overview
XDC100SA is a single-channel programmable DC supply family with 12 models spanning 36 to 360 W. Selected models reach 150 V or 10 A, with list sequencing, four-wire remote sense and DVM measurements.
Additional product details
The XGY XDC100SA series comprises 12 programmable DC power supply models ranging from 36W to 360W, designed for R&D, design validation, industrial automation, scientific research, and education workflows requiring precise voltage and current control. XDC100SA ripple is ≤ 5 mVrms, ≤ 5 mArms by model.
Where the XDC100SA workflow depends on remote control, note that RS232 is the only standard interface; USB, LAN, and RS-485 are ordering options that must be specified at quotation.
Key Capabilities & Applications
Fine supply settings
Setting resolution is 0.1 mV / 0.1 mA. Constant-voltage ripple is 3 to 5 mVrms by model.
Sequences and measurements
List mode, adjustable slew rate, waveform display, USB data logging and DVM voltage/resistance measurements support bench tests.
Local and remote control
A 4.3-inch color display and rotary knob provide local setup. RS232 communication is standard; USB, LAN and RS485 communication interfaces are optional.
Common applications
- R&D bench power delivery
- Design validation
- Industrial automation
- Scientific research and education
Applications and test requirements
R&D bench power delivery
Precise output with 0.1 mV / 1 µA resolution for device characterization.
Design validation
Industrial automation
Scientific research and education
Technical Specifications
| Parameter | Specification |
|---|---|
| Voltage | Up to 150 V (model dependent) |
| Current | Up to 10 A (model dependent) |
| Power range | 36 to 360 W |
| Ripple and noise | ≤ 5 mVrms3 to 5 mVrms by model, constant voltage mode |
| Setting resolution | 0.1 mV / 0.1 mA |
| Setting accuracy | Voltage ≤ 0.1% + 5 mV; current ≤ 0.2% + 1 mA25 °C ±5 °C |
| Remote sense | 4-wire remote sense |
| Interface | RS232 standard; optional USB, LAN, RS-485 |
View all 19 specifications
| Parameter | Specification |
|---|---|
| Load regulation | 0.05% + 5 mV to 0.05% + 10 mVConstant voltage mode |
| Line regulation | 0.05% + 5 mV to 0.05% + 10 mVConstant voltage mode |
| Protection | OVP / OCP / OTP |
| Front panel | 4.3-inch LCD color display, rotary knob with fine/coarse adjustment, output on/off control |
| Dimensions | 230 × 110 × 395 mm |
| Net weight | 5.6 to 9.9 kg (model dependent) |
| At a glance | |
| Channels | 1Stated for the series |
| Display resolution | 0.1 mV / 1 µAStated for the series |
| Rise time | < 20 ms |
| Measurement functions | DVM voltage and resistance measurement |
| Preset storage | 100 presets; hotkey recall of up to 6 configurations |
Specifications are subject to change without notice.
Models, Configuration & Compatibility
XDC100SA
Model comparison (1)
| Model | Voltage | Current | Power | Voltage ripple | Current ripple | Net weight |
|---|---|---|---|---|---|---|
| XDC100SA-20-3 | 20 V | 3 A | 60 W | 3 mVrms | 3 mArms | 6.9 kg |
| XDC100SA-20-6 | 20 V | 6 A | 120 W | 3 mVrms | 3 mArms | 7.2 kg |
| XDC100SA-20-10 | 20 V | 10 A | 200 W | 5 mVrms | 5 mArms | 7.8 kg |
| XDC100SA-36-1 | 36 V | 1 A | 36 W | 3 mVrms | 3 mArms | 5.6 kg |
| XDC100SA-36-3 | 36 V | 3 A | 108 W | 3 mVrms | 3 mArms | 6.9 kg |
| XDC100SA-36-6 | 36 V | 6 A | 216 W | 3 mVrms | 3 mArms | 8 kg |
| XDC100SA-36-10 | 36 V | 10 A | 360 W | 5 mVrms | 5 mArms | 9.9 kg |
| XDC100SA-60-1 | 60 V | 1 A | 60 W | 3 mVrms | 3 mArms | 7.8 kg |
| XDC100SA-60-3 | 60 V | 3 A | 180 W | 3 mVrms | 3 mArms | 8.2 kg |
| XDC100SA-60-5 | 60 V | 5 A | 300 W | 3 mVrms | 3 mArms | 9 kg |
| XDC100SA-100-1 | 100 V | 1 A | 100 W | 3 mVrms | 3 mArms | 7.8 kg |
| XDC100SA-150-1 | 150 V | 1 A | 150 W | 3 mVrms | 3 mArms | 7.8 kg |
Ripple and noise figures: 25 °C ±5 °C. Model-specific table values govern; the source feature summary also gives a broader ≤3 mVrms claim.
Model selection details
Size the XDC100SA model from the required voltage-current corner rather than from the 360 W family maximum power alone, then confirm that the constant-voltage load and line regulation figures in the specification table meet the measurement uncertainty budget for the DUT.
Control interfaces and software
RS232 is standard; USB, LAN and RS485 communication interfaces are optional. The instrument supports list sequencing, adjustable slew rate and data logging.
RS232 · Optional USB · Optional LAN · Optional RS485
Technical Resources
Selection guidance
Format: Single-channel linear DC source
Coverage: Up to 150 V voltage and 10 A current by model; 36 to 360 W power; no more than 5 mVrms ripple
Best for: Low-ripple R&D and validation work needing one programmable linear DC output and fine measurement resolution.
Compare products in the Power Supplies categorySend the operating envelope, configuration and acceptance evidence you need; the quotation confirms model, options and delivery documentation.


